AM385HPM PARAMETER
Item
Function
Test conditions and requirements
Rated voltage
6V-12V
Operating voltage
5V-13V
No-load current
700mA
Load current
1500mA
Fillwith 50KPa gas into 100CC bottle to test the working current of the product.
Air flow
5L
Vacuum Level
>75Kpa
Noise
65dB
Fill with 50Kpa gas into 100CC bottle to test the product's working noisy(Ambient noise ≤ 45dB)
Service life
Carbon brush
>500H
Metal brush
N/A
Operating environment
Temperature: 5-50°C
Humidity: 30-80%
Fluid Usage
Air
Weight
95g