AM395EPV PARAMETER
Item
Function
Test conditions and requirements
Rated voltage
12V
Operating voltage
10.8V—13.2V
Rated current
460mA
Load current
530mA
Fillwith 50KPa gas into 100CC bottle to test the working current of the product.
Air mass flow
8.0L
Pressure
>80Kpa
Noise
65dB
Fill with 50Kpa gas into 100CC bottle to test the product's working noisy(Ambient noise ≤ 45dB)
Service life
Carbon brush
>350H
Metal brush
>100H
Operating environment
Temperature:≤50°C
Humidity:75%
Using the fluid
Air
Monomer weight
131g